Gabung | daftar
Tentang Kami
Rumah > Label > Perawatan Pemutus Sirkuit Vakum

Perawatan Pemutus Sirkuit Vakum

Vacuum Circuit Breaker Maintenance Vacuum circuit breakers (VCBs) are critical components in electrical distribution systems, offering reliable interruption of current in medium-voltage applications. Proper maintenance is essential to ensure their longevity, performance, and safety. Below are key maintenance practices for VCBs: 1. Visual Inspection Regular visual checks should be performed to identify signs of wear, contamination, or damage. Inspect the breaker enclosure for cracks, corrosion, or loose connections. Verify the condition of insulating components, such as bushings and supports, for cracks or carbon tracking. Ensure that mechanical linkages operate smoothly without obstruction. 2. Contact Resistance Measurement High contact resistance can lead to overheating and reduced breaking capacity. Use a micro-ohmmeter to measure the resistance across the main contacts. Compare readings with manufacturer specifications; excessive resistance may indicate contact erosion or contamination, necessitating cleaning or replacement. 3. Insulation Resistance Testing Perform insulation resistance tests (e.g., using a megohmmeter) on the vacuum interrupter and associated insulation. Low resistance values suggest moisture ingress or insulation degradation, requiring further investigation or drying. 4. Vacuum Integrity Check A loss of vacuum in the interrupter can compromise breaking performance. While direct measurement is complex, indirect methods include: - High-Potential (Hi-Pot) Test: Apply a high voltage to check for dielectric strength. - Contact Travel Analysis: Excessive wear may indicate vacuum degradation. If failure is suspected, replace the vacuum interrupter. 5. Mechanical Operation Test Verify the breaker’s mechanical operation by performing open/close cycles manually and electrically. Check for proper contact alignment, smooth movement, and correct timing. Lubricate moving parts as recommended, using approved grease to prevent friction-related failures. 6. Secondary Circuit Inspection Inspect control wiring, relays, and auxiliary contacts for loose connections or corrosion. Test protective relays and trip circuits to ensure proper coordination. 7. Cleaning and Lubrication Remove dust, moisture, or conductive deposits from surfaces using non-abrasive cleaners. Apply lubrication sparingly to hinges, rollers, and sliding surfaces to prevent sticking. 8. Functional Testing After maintenance, conduct a full operational test under load conditions (if possible) to validate performance. Record all measurements for trend analysis. Conclusion Proactive maintenance of VCBs minimizes downtime and prevents catastrophic failures. A structured schedule—combining visual inspections, electrical tests, and mechanical checks—ensures reliability. Always adhere to safety protocols and manufacturer guidelines during maintenance activities. (Word count: 500)

Produk

Kategori:
Tidak ada hasil pencarian!

Berita

Kategori:

Kasus

Kategori:
Tidak ada hasil pencarian!

Video

Kategori:
Tidak ada hasil pencarian!

Download

Kategori:
Tidak ada hasil pencarian!

Rekrutmen

Kategori:
Tidak ada hasil pencarian!

Produk yang direkomendasikan

Tidak ada hasil pencarian!
Hubungi kami

Telepon: +8613736779975

Email: penjualan@vcbbreaker.com

Perairan: 66 Road, Zona Pengembangan Pembangunan Ekonomi Ikonik, Zheji, Cina

Hak Cipta ©  2025 Eberry Electric Group  Semua hak dilindungi undang-undang

Peta situs

Situs web ini menggunakan cookie untuk memastikan Anda mendapatkan pengalaman terbaik di situs web kami.

Menerima menolak